Power Input Unit (PIU)

Power Input Unit (PIU, VIU)

EKE Trainnet® PIU Front EKE Trainnet® PIU Side EKE Trainnet® PIU with DC Converter Front EKE Trainnet® VIU Front EKE Trainnet® VIU Side
TECHNICAL SPECIFICATIONS

Standards:

EN 50155
EN 45545

Dimensions (W x H x D):
4 TE x 3 U x 160 mm
Weight:
100 - 150 g
Input Voltage:
24, 36-52, 72 or 110 V DC available
Other on request
Temperature Range (operational):
-40 °C…+70 °C
MTBF (40 ºC ambient temperature):
44 570 000 h
Output Voltage (optional):
12 V DC (from PSV)

Technical Data DC Converter option
Weight:
350 g
Input Voltage:
24 or 110 V DC available
Others on request
MTBF (40 ºC ambient temperature):
500 000 h
Output Voltage and Power:
See table

Vehicle Identification Unit (VIU)
Weight:
155 g
Input Voltage:
110 V DC
MTBF (40 ºC ambient temperature):
5 360 000 h

module functions

The Trainnet® Power Input Unit (PIU) is used to pass train battery voltage to the Trainnet® PSV module, thus powering the entire Trainnet® systems.


key features

The Trainnet® PIU input voltages can be 24 V DC (PIU2056A), 36 to 52 V DC (PIU2510A), 72 V DC (PIU2280A) or 110 V DC (PIU2219A). A Trainnet® PSV with a similar input voltage must be selected.


options

Isolated DC Converter Output: An isolated DC/ DC converter may be installed as an option to provide power to any external equipment. If required, the output voltage may be switched off during the system reset in order to force hard-resets of external equipment. Currently available PIU modules with DC Converter Ouput are listed in the table below. We can also provide you with another versions upon request.


MODULE
REFERENCE
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
POWER
PIU2034A 24 V DC 16 V DC 17 W
PIU2023A 110 V DC 16 V DC 17 W
PIU3392A 110 V DC 24 V DC 46 W
PIU3394A 110 V DC 24 V DC 25 W

Vehicle Identification Unit (VIU): The Trainnet® VIU (Vehicle Identification Unit) has the functionalities of the Trainnet® PIU, and in addition, provides an interface for Electronic Serial Number (ESN). An Electronic Serial Number (ESN) dongle can be connected to VIU for device identification and configuration.