The EKE-Trainnet® Pt100/Pt1000 Temperature Sensor Input (PTI) module is SIL 2 certified.
Signals are acquired from the Pt100 (PTI2037) or Pt1000 (PTI3593) temperature sensors (resistance measurement) and converted into temperature values expressed in degrees Celsius, making the values available to the train computer’s Central Processing Unit (CPU).
The EKE-Trainnet® PTI can be used as part of an EKE-Trainnet® Train Control and Management System, Vehicle Control Unit or Event Recorder. Alternatively, the EKE-Trainnet® PTI can be fitted into the EKE-Trainnet® Remote Input Output System.
The EKE-Trainnet® PTI has six measurement channels which can measure temperature within the -110 to +325 °C range with over range indication. Each channel is isolated from each other, thus a fault in one channel will not affect the others. The temperature sensors can be connected using 2-wire, 3-wire or 4-wire schemes, providing flexibility.
The embedded processor also implements diagnostic functions and reports to the train computer’s CPU module if it suspects that the input values cannot be trusted. The EKE-Trainnet® PTI detects the temperature sensor as well as cable faults and input channel faults.
The measurement resolution is 0.01 °C, with accuracy better than ±1 °C within the measurement range.
The module development is based on the railway standards EN 50126, EN 50716 (previously EN 50128) and EN 50129 in accordance with safety integrity level SIL 2. A non-SIL version of the module is also available.
The module has its own 32-bit embedded processor that uses factory calibration values to convert measurement values to degrees Celsius with the best possible accuracy.
For almost four decades, EKE-Electronics has supplied TCMS solutions to train manufacturers, operators, and integrators worldwide. Using our modular EKE-Trainnet® system, we provide solutions for system integration, train automation, communications, diagnostics, and safety.
EKE-Electronics Ltd.
Piispanmäentie 5
02240 Espoo
Finland
4 TE x 3 U x 160 mm
160 g
5 V DC ± 5 % (310 mA typ., 400 mA max.)
-40 °C…+70 °C
2 490 000 h
DIN41612-F48 (at front)
RS-485
6 Pt100 sensor
2-wire, 3-wire or 4-wire
-110 ºC to + 325 ºC
0.01 ºC
Better than ± 1 ºC (3- or 4-wire)