Analogue Ouput Module (AOM)

Analogue Output Module (AOM)

EKE Trainnet® AOM Front EKE Trainnet® AOM Side
TECHNICAL SPECIFICATIONS

Standards:

EN 50126
EN 50128
EN 50129
EN 50155
EN 45545
SIL-2

Dimensions (W x H x D):
4 TE x 3 U x 160 mm
Weight:
165 g
Input Power:

5 V DC ± 5 % (1 A typ., 3A max.)
Temperature Range (operational):
-40 °C…+70 °C
MTBF (40 ºC ambient temperature):

770 000 h (AOM2610A)
I/O Connector:

DIN41612-F48 (at front)
Host Interface:
RS 485
Current Output Mode:

4…20 mA
1 µA resolution
Voltage Output Mode:

-10…+10 V
1 mV resolution
PWM Outputs:
Selectable base frequency 10 Hz to 10 kHz
Pulse width adjustable with 0.1% resolution
Output level 15 V

module functions

The Trainnet® Analogue Output Module (AOM) provides a standard interface for analogue output signals. The Trainnet® AOM receives instructions from the train computer's CPU Module and sends analogue signals to sub-systems accordingly.

The Trainnet® AOM can be used as a part of a Trainnet® TCMS, VCU or Event Recorder. Alternatively, the Trainnet® AOM can be fitted into the Trainnet® Remote I/O Module (RIOM).


key features

The module has 4 individually isolated analogue output groups. All groups are identical and have 4 analogue output channels. Each group has two PWM outputs.

By default, 2 channels are configured as current loop transmitters with integrated loop supply (current mode) and 2 channels as bipolar voltage output and two digital pulse width modulation outputs (voltage mode). The channel configurations can easily be changed from current mode to voltage mode and vice-versa, depending on your needs. The Trainnet® AOM is able to provide current loop supply voltage internally: there is no need for an external power supply. Configurable ranges are from 4 to 20 mA for current and from -10 to +10 V for voltage.

Each output channel has parameters for calibration (factory set), and diagnostics to detect short or open in current loop and short in voltage output. Outputs are factory calibrated.

The module has its own 32-bit embedded processor to manage serial communication with the train computer's CPU module.  The embedded processor also implements diagnostic functions and reports to the system CPU module if it suspects that the output values cannot be trusted.

The module has an RS 485 serial bus interface for connecting to the train computer.